Clamping fixation thermocouple with smaller plug adopts φ0.5~φ4 armored thermocouple. Armored components are directly connected to measured medium, with quick heat response. Without fixation, its compensation lead wire is connected with plug, with tingue wiring terminal. It is reliable for wiring.
Graduations: K and J.
技术参数
1) Variety, measuring range and tolerance
Type
Graduation
Sheathing material
Armoring Diameter
d/mm
measuring range
℃
Thermal Couple Level And Tolerance
Ⅰ
Ⅱ
WRNK
Ni-Cr – Ni-Si
K
06Cr18Ni11Ti
φ0.5、φ1
0~400
±1.5℃
or
±0.4%t
±2.5℃
or
±0.75%t
φ1.5、φ2
0~600
φ3、φ3.2、φ4
0~800
GH3030
φ0.5、φ1
0~500
φ1.5、
0~800
φ2、φ3、φ3.2
0~900
φ4
0~1000
WRFK
Fe – Cu-Ni
J
06Cr18Ni11Ti
φ0.5、φ1
0~400
φ1.5、φ2
0~500
φ3、φ3.2、φ4
0~600
2) connection size and insert depth
Armoring Diameter
d/mm
Connection method
Insertion Depth
mm
Compensation Lead Length
mm
φ0.5
Smaller Yellow Flat Plug Is Fixed Onto Armored Thermal Couple.