General thermocouple and resistor
Clamping Fixation thermocouple With Smaller Plug
Clamping Fixation thermocouple With Smaller Plug
产品概述

  Clamping fixation thermocouple with smaller plug adopts φ0.5~φ4 armored thermocouple. Armored components are directly connected to measured medium, with quick heat response. Without fixation, its compensation lead wire is connected with plug, with tingue wiring terminal. It is reliable for wiring.


 Graduations: K and J.


技术参数

1) Variety, measuring range and tolerance

Type

Graduation

Sheathing material

Armoring Diameter

d/mm

measuring range

Thermal Couple Level And Tolerance

WRNK

Ni-Cr – Ni-Si

K

06Cr18Ni11Ti

φ0.5、φ1

0~400

±1.5℃

 or

±0.4%t

±2.5℃

 or

±0.75%t

φ1.5、φ2

0~600

φ3、φ3.2、φ4

0~800

GH3030

φ0.5、φ1

0~500

φ1.5、

0~800

φ2、φ3、φ3.2

0~900

φ4

0~1000

WRFK

Fe – Cu-Ni

J

06Cr18Ni11Ti

φ0.5、φ1

0~400

φ1.5、φ2

0~500

φ3、φ3.2、φ4

0~600

2) connection size and insert depth

Armoring Diameter

d/mm

Connection method

Insertion Depth

mm

Compensation Lead Length

mm

φ0.5

Smaller Yellow Flat Plug Is Fixed Onto Armored Thermal Couple.

Any Length

Determined by user

φ1

φ1.5

φ2

φ3

φ3.2

φ4