In the production of oil, gas, chemical and other industries, inflammable, explosive, corrosive chemical gas, steam and liquid is very common. In order to achieve industrial production automation, workers need a temperature sensor to automatically measure and control the process, while the use of aluminum alloy explosion-proof junction box can no longer meet the safety requirements for flame-proof .
Flameproof thermocouple, thermal resistance, explosion-proof by the National Safety Supervision and Inspection Station test qualified and issued an explosion-proof series of product certification.
It uses all stainless steel junction box for Exd Ⅱ BT4 ~ 5, Exd Ⅱ CT1 ~ 6 and requires the highest level of protection to IP65 with a corrosive and explosive atmosphere of the place.
1) temperature and tolerance
Type | Graduation | Tolerance level |
level Ⅱ |
Measuring range | Permissible difference |
Nicrsi-Nisimg | N | -40~1200℃ | ±2.5℃ or ±0.75%∣t∣ |
Nicr-Nisi | K |
Nicr-Cuni | E | -40~900℃ | ±2.5℃ or ±0.75%∣t∣ |
Fe-Cuni | J | -40~750℃ |
Cu-Cini | T | -40~350℃ | ±2.5℃ or ±0.75%∣t∣ |
Ptrh10-Pt | S R | 0~600℃ | ±1.5℃ |
Ptrh13-Pt | 600~1600℃ | ±0.25%∣t∣ |
Ptrh30-Ptrh | B | 600~1700℃ | ±1.5℃~±0.25%∣t∣ |
Type | Graduation | Measuring range | Tolerance level |
Pt Resistor | Pt100 | -200~500℃ | level A:±(0.15+0.002∣t∣)℃ |
level B:±(0.30+0.005∣t∣)℃ |
Cu Resistor | Cu50 | -50~100℃ | ±(0.30+0.006∣t∣)℃ |
Cu100
|
Type | Graduation | Temperature range | Tolerance level |
Pt Resistor | Pt100 | -200~500℃ | level A:±(0.15+0.002∣t∣)℃ |
level B:±(0.30+0.005∣t∣)℃ |
Cu Resistor | Cu50 | -50~100℃ | ±(0.30+0.006∣t∣)℃ |
Cu100 |
2) junction box: small stainless steel junction box (P2), large stainless steel junction box (P1).
3) protection tube: overall drilling, diameter 12, Phi 16, Phi 20, optional material.
4 process connection: fixed screw connection, the specifications are M27 x 2, M33 x 2, NPT1/2, NPT3/4, NPT1, etc., can also choose the flange connection.
5) temperature sensor: single and double armored elements Phi 3 and phi 4, Phi 5, phi 6, Phi 8 optional.