Thermocouple and resistor for oil & chemical industry
Flameproof thermocouple, thermal resistance
Flameproof thermocouple, thermal resistance
产品概述


  In the production of oil, gas, chemical and other industries, inflammable, explosive, corrosive chemical gas, steam and liquid is very common. In order to achieve industrial production automation, workers need a temperature sensor to automatically measure and control the process, while the use of aluminum alloy explosion-proof junction box can no longer meet the safety requirements for flame-proof .


Flameproof thermocouple, thermal resistance, explosion-proof by the National Safety Supervision and Inspection Station test qualified and issued an explosion-proof series of product certification.


  It uses all stainless steel junction box for Exd Ⅱ BT4 ~ 5, Exd Ⅱ CT1 ~ 6 and requires the highest level of protection to IP65 with a corrosive and explosive atmosphere of the place.


 


技术参数

1) temperature and tolerance


Type

Graduation

Tolerance level

level Ⅱ

Measuring range

Permissible difference

Nicrsi-Nisimg

N

-40~1200℃

±2.5℃ or

±0.75%∣t∣

Nicr-Nisi

K

Nicr-Cuni

E

-40~900℃

±2.5℃ or

±0.75%∣t∣

Fe-Cuni

J

-40~750℃

Cu-Cini

T

-40~350℃

±2.5℃ or

±0.75%∣t∣

Ptrh10-Pt

S

R

0~600℃

±1.5℃

Ptrh13-Pt

600~1600℃

±0.25%∣t∣

Ptrh30-Ptrh

B

600~1700℃

±1.5℃~±0.25%∣t∣

Type

Graduation

Measuring range

Tolerance level

Pt Resistor

Pt100

-200~500℃

level A:±(0.15+0.002∣t∣)℃

level B:±(0.30+0.005∣t∣)℃

Cu Resistor

Cu50

-50~100℃

±(0.30+0.006∣t∣)℃

Cu100



Type

Graduation

Temperature range

Tolerance level

Pt Resistor

Pt100

-200~500℃

level A:±(0.15+0.002∣t∣)℃

level B:±(0.30+0.005∣t∣)℃

Cu Resistor

Cu50

-50~100℃

±(0.30+0.006∣t∣)℃

Cu100





2) junction box: small stainless steel junction box (P2), large stainless steel junction box (P1).

3) protection tube: overall drilling, diameter 12, Phi 16, Phi 20, optional material.

4 process connection: fixed screw connection, the specifications are M27 x 2, M33 x 2, NPT1/2, NPT3/4, NPT1, etc., can also choose the flange connection.

5) temperature sensor: single and double armored elements Phi 3 and phi 4, Phi 5, phi 6, Phi 8 optional.