Thermocouple and resistor for oil & chemical industry
Explosion-proof corrosion, leakage, wear thermocouple, thermal resistance
Explosion-proof corrosion, leakage, wear thermocouple, thermal resistance
产品概述


  In order to prevent electrical connection as well as the junction box body thread connection eroded by the harmful atmosphere, this product uses stainless steel explosion-proof connecting box. Its protecting tube uses the special sleeve fastening armored temperature measurement component, forms absolutely sealed structure. to prevent outer pipes leakage of oil or gas after abrasion,


  There are two structures and different materials to choose for the tubes. One is alloy tubes with different materials and spray coating Ni60WC40 outside as requested  . Another adopts overall drilling corrosion proof and heat proof alloy materials as the anti-wear head (tube). 


  This series of products is suitable for the temperature measurement of production process where certain speedy solid particle, liquid or gas is generated. Its indispensable for the temperature measurement of circulative vulcanization bed (CFB), incinerator and oil refine factory.


 


技术参数

1) Temperature and Tolerance

Type

Graduation

Tolerance level

level Ⅱ

Measuring range

Permissible difference

Nicrsi-Nisimg

N

-40~1200℃

±2.5℃ or

±0.75%∣t∣

Nicr-Nisi

K

Nicr-Cuni

E

-40~900℃

±2.5℃ or

±0.75%∣t∣

Fe-Cuni

J

-40~750℃

Cu-Cini

T

-40~350℃

±2.5℃ or

±0.75%∣t∣

Ptrh10-Pt

S

R

0~600℃

±1.5℃

Ptrh13-Pt

600~1600℃

±0.25%∣t∣

Ptrh30-Ptrh

B

600~1700℃

±1.5℃~±0.25%∣t∣

Type

Graduation

Measuring range

Tolerance level

Pt Resistor

Pt100

-200~500℃

level A:±(0.15+0.002∣t∣)℃

level B:±(0.30+0.005∣t∣)℃

Cu Resistor

Cu50

-50~100℃

±(0.30+0.006∣t∣)℃

Cu100



2) junction box: small stainless steel junction box (P2), large stainless steel junction box (P1).

3) electrical outlet: M20 * 1.5, M22 * 1.5, NPT1/2".

Hardness of wear head: HRC62 ~ 70, ~ 4.

5) protection class: IP65.

6) explosion proof grade: Exd II BT4 ~ 5, Exd II CT1 ~ 6.

7) nominal pressure: threaded connection 10Mpa, flange connection 2.5 Mpa.

8) temperature sensor: single and double armored elements Phi 3 and phi 4, Phi 5, phi 6, Phi 8 optional.