Thermocouple and resistor for other uses
Handled Flat Surface thermocouple
Handled Flat Surface thermocouple
产品概述

Handheld flat surface thermocouple selects φ5~φ8 armored thermocouple, probe tip with a raised cylinder, to limit the distance between tested objects and ribbon temperature element, to prevent damage of temperature testing component. With a straight-held large handles , which has spring-soft handle at the end, the lead wire is connected to the portable digital tachometer display’s flat yellow plug, easy for connection of secondary meters. The testing length is according to users’ need, applied to the measurement of casting, molding, bearing, glassware and other stationary objects surface temperature


The distance between components and insulation resistor is not less than 20M (500V Ω DC ).


Continuous measurement time : in 400C above , the continuous use of 1 minute. 


Graduation:  K, E


技术参数

1) Variety, measuring range and tolerance


TypeGraduationArmoring MaterialArmoring DiameterMeasurement ScopeThermal Couple Level And Tolerance
WRNM-102AK06CR18Ni11Tiφ5、φ6、φ80~800III
GH3030φ50~900±1.5℃or±0.4%t±2.5℃or±0.75%t
φ6、φ80~1100
WREM-102AE06cR18Ni11Tiφ5、φ6、φ80~700


2) handle the form of size and insert depth

Armoring Diameter d/mm

Insertion Depth/mm

Handle Form
φ8300~1500

Or Decided By Clients

Larger Straight Hand

φ6
φ5