Type metal, alloy solution thermocouple uses the high temperature special quartz glass outer tube, inside installs the small diameter corundum tube or the quartz tube, and flushes the protection atmosphere to form the double layer anti-corrosion temperature nonmetallic protective cover ), The protection tube is equipped with corundum tube or armored structure composed of temperature thermocouple, can be directly into the copper solution, aluminum solution, copper nickel, aluminum-nickel alloy solution and other metal solution temperature
技术参数
1) model specifications
Type
Graduation
measuring range
℃
Precision Level
Protecting Tube Material
WRSH-□□0
S
0~1350
Ⅱ
Special High Temperature Quartz Tube
WRRH-□□0
R
2) standard size
Type
Graduation
Protecting Tube Specifications
Process connection
Junction box form
Electric Interface
Inserted Section
mm
Total length
mm
WRSH-□□0
S
φ16×500
≤2000,Specific length determined by the user
1
Non fixing device
2
Splash proof
M20×1.5
M22×1.5
2
Thread connection
M27×2
or
M33×2
3
Waterproof type
WRRH-□□0
R
3
Movable flange
4
Fixed flange connection
(Specification determined by user)
5
Large cavity junction box
Note: products of other specifications can be provided according to user's requirements.