Thermocouple and resistor for oil & chemical industry
Series Anti-Explosion thermocouple And Resistor With Variable Diameter
Series Anti-Explosion thermocouple And Resistor With Variable Diameter
产品概述


  In the production of oil, gas, chemical and other industries, inflammable, explosive, corrosive chemical gas, steam and liquid is very common. In order to achieve industrial production automation, workers need a temperature sensor to automatically measure and control the process, while the use of aluminum alloy explosion-proof junction box can no longer meet the safety requirements for flame-proof .


  Serial anti-explosion changeable-diameter thermal couple and resistor adopt full stainless steel junction box (flat junction box) and could be applied in ExdⅡBT4~5, ExdⅡCT1~6 which demands the highest level of protection---IP65, where corrosion and explosive atmosphere is around.



技术参数

1) temperature and tolerance

Type

Graduation

Tolerance level

level

level 

Temperature range

Tolerance

Temperature range

Tolerance level

Nicrsi-Nisimg

N

-401000

±1.5℃ or

±0.4%∣t∣

-401200

±2.5℃ or

±0.75%∣t∣

Ni-Cr – Ni-Si

K

Ni-Cr – Cu-Ni

E

-40800

±1.5℃ or

±0.4%∣t∣

-40900

±2.5℃ or

±0.75%∣t∣

Fe–CuNi

J

-40750

-40750

Cu–CuNi

T

-40350

±1.5℃ or

±0.4%∣t∣

-40350

±2.5℃ or

±0.75%∣t∣

Ptrh10-Pt

S

R

01100

±1

0600

±1.5

Ptrh13-Pt

11001600

±【1+0.003(t-1100)】℃

6001600

±0.25%∣t∣

Ptrh30-Pt6

B

——

6001700

±1.5℃~±0.25%∣t∣

 

Type

Graduation

Temperature range

Tolerance level

Pt Resistor

Pt100

-200500

level A:±(0.15+0.002∣t∣)℃

level B:±(0.30+0.005∣t∣)℃

Cu Resistor

Cu50

-50100

±(0.30+0.006∣t∣)℃

Cu100

2) Junction box: stainless steel flat explosion-proof junction box, optional small stainless steel junction box (P2) or large stainless steel junction box (P1).

3) protection tube: variable diameter overall drilling, optional material.

4) Process connection: threaded connection, specifications are M27 × 2, M33 × 2, NPT1 / 2 ", NPT3 / 4", NPT1 ", etc., can also be used flange connection.

5) temperature measurement components: single, double armored components φ3, φ4, φ5, φ6, φ8 optional.

6) can be equipped with integrated temperature transmitter, temperature change optional intelligent or ordinary type.