Thermocouple and resistor for oil & chemical industry
Assembled explosion-proof thermocouple, thermal resistance
Assembled explosion-proof thermocouple, thermal resistance
产品概述

  Assembled explosion-proof thermocouple, thermal resistance designed according to explosion-proof standard GB3836 of the International Electrotechnical Commission IEC standard ,the use of two-chamber explosion-proof structure, the replacement of measurement components is simple, safe and reliable.


  Explosion-proof mark d Ⅱ BT4, apply to below Ⅱ B, ignition temperature above T4 or more, with explosive gas temperature measurement.



技术参数

1) measurement range and tolerance

Type

Graduation

Protection tube material

measuring range

Temperature measurement component level and tolerance

Ni-Cr – Ni-Si

K

06Cr18Ni11Ti

-40850

±1.5℃ or

±0.4%∣t∣

±2.5℃ or

±0.75%∣t∣

1Cr25Ni20

01000

GH30Alloy

01100

3YC-52Alloy

Single01200

Double branch01100

Ni-Cr – Cu-Ni

E

06Cr18Ni11Ti

Single-40650

Double branch-40550

 PtResistor

Pt100

06Cr18Ni11Ti

0Cr18Ni12Mo2Ti

-200500

A

±(0.15+0.002∣t∣)℃

B

±(0.30+0.005∣t∣)℃

CuResistor

Cu50

-50100

±(0.30+0.006∣t∣)℃

2) the form and depth of insertion

Junction Box

Fixed device form

Protection tube

Nominal pressure

MPa

Insertion depth

Mm

Code

Name

Code

Name

type

End form

4

Alloy Anti-Explosion Junction Box

1

Non-Fixed

φ16

φ12

Straight

Atmospheric pressure

100,150,

200,250,

300400

500,750

1000

When the thermal resistance protection tube diameter isφ16, increase

1500And2000two types

 

2

Fixed Threaded

10

3

Movable flange

Atmospheric pressure

4

Fixed flange

Depending on flange form