Assembled explosion-proof thermocouple, thermal resistance designed according to explosion-proof standard GB3836 of the International Electrotechnical Commission IEC standard ,the use of two-chamber explosion-proof structure, the replacement of measurement components is simple, safe and reliable.
Explosion-proof mark d Ⅱ BT4, apply to below Ⅱ B, ignition temperature above T4 or more, with explosive gas temperature measurement.
技术参数
1) measurement range and tolerance
Type
Graduation
Protection tube material
measuring range
℃
Temperature measurement component level and tolerance
Ⅰ
Ⅱ
Ni-Cr – Ni-Si
K
06Cr18Ni11Ti
-40~850
±1.5℃ or
±0.4%∣t∣
±2.5℃ or
±0.75%∣t∣
1Cr25Ni20
0~1000
GH30Alloy
0~1100
3YC-52Alloy
Single0~1200
Double branch0~1100
Ni-Cr – Cu-Ni
E
06Cr18Ni11Ti
Single-40~650
Double branch-40~550
PtResistor
Pt100
06Cr18Ni11Ti
0Cr18Ni12Mo2Ti
-200~500
A
±(0.15+0.002∣t∣)℃
B
±(0.30+0.005∣t∣)℃
CuResistor
Cu50
-50~100
—
±(0.30+0.006∣t∣)℃
2) the form and depth of insertion
Junction Box
Fixed device form
Protection tube
Nominal pressure
MPa
Insertion depth
Mm
Code
Name
Code
Name
type
End form
4
Alloy Anti-Explosion Junction Box
1
Non-Fixed
φ16
φ12
Straight
Atmospheric pressure
100,150,
200,250,
300,400
500,750
1000
When the thermal resistance protection tube diameter isφ16, increase